English

Low voltage

RP – Industrial switchgear up to 4000 A

RP industrial switchgear is characterized by simple and clear electrical connection layouts and has a design that guarantees safe operation. Thanks to the high degree of IP protection (IP 4X – IP 54), RP switchgears can be used directly next to machinery and equipment. A very important aspect in the construction of our switchboards is their reliability and easy expandability.

Main advantages

  • Resistance to mechanical damage.
  • Clear layout of connections.
  • Safety of operation.
  • Operational reliability.
  • Easy expandability.

Equipment configurations

  • A.MZ – power module – equipped with a disconnector (max. 4000 A) or power switch (max. 4000 A), having the ability to block opening under load, cable entry from above or below by means of rail or cable connections.
  • B.MS – Coupling module – operation in SZR systems together with power supply modules, cable entry from above or below by means of rail or cable connections.
  • B.MP – outflow module – Equipped with strip fuse disconnectors, box fuse disconnectors or power circuit breakers (from 160A to 1250A), available apparatuses: NSL, SL, ARS, LTL, SLBM, RBK, RB-2(s), others, insert size gr. 00 – 4.
  • D.BK – reactive power compensation module – Inductive and capacitive reactive power compensation up to 400 kVar.
  • E. other modules – Such as control or communications.

Dimensions

  • Dimensions adapted to the type, amount of equipment and individual needs of the customer. Typical implementations:
  • height: 1800/2000/2200 mm;
  • width: 400/600/800/850/1000/1050/1250/1400 mm;
  • depth: 250/300/400/600/800 mm.

Modular housing

  • A small-sized, lightweight modular skeletal structure made of galvanized steel or aluminum profiles connected by cast connectors made of aluminum or polyamide, allowing tool-free connection of individual elements and ensuring adequate rigidity of the structure.
  • High mechanical strength and a degree of protection that prevents the ingress of dust and mechanical damage.
  • Fully shielded, covers made of steel sheet coated with anti-corrosion, powder coated in any color, made in a fixed or tilting version that allows inspection and examination with a thermal imaging camera.
  • Internal space with separated parts: functional modules, current paths.
  • Allows you to change the power supply side independently, either by repositioning the switchgear power module or swapping it with the metering module.
  • Connection of individual modules made by screw connections (without riveting or welding) allows quick disassembly of modules, bringing the switchboard in modules to the place of foundation in the room (lack of space) and their reassembly.
  • Set on an additional frame, matching the dimensions of the cable channel.
  • The dimensions of the switchboard are arbitrary, adapted to the individual needs of the customer.
  • Connecting a clique of modules at a 90-degree angle.
  • Handles to allow transport by crane or overhead crane.

Frequently asked questions

What is your delivery time?

Standard delivery time is approximately 6-8 weeks depending on the order. Please contact us to arrange a more detailed delivery date.

What effects do your charging stations have?

We offer an extensive range of products, encompassing both AC and DC EV chargers featuring diverse equipment configurations and power outputs. The power spectrum of our EV chargers includes:

  • AC 3.7-43 kW
  • DC 40-480 kW

Who installs charging stations?

Charging stations are only installed by Swedish certified electricians.

How fast do your stations charge?

The fastest DC chargers can charge a car in up to half an hour. Charging time for electric vehicles depends on:

  • EV charger power
  • battery capacity
  • the power of the converter installed in the car.

Which station is best for private use?

The best choice for private use are small stations such as:

  • EVB E-wall - mounted in the wall not only makes it much easier to use, but also blends almost seamlessly into the façade and improves its aesthetics.
  • EVB Wallbox 2M AC - it can be hung on the wall in the garage, thanks to which it takes up little space and can charge two cars at the same time. Charging point power up to 22 kW.

How is the advertising content on EVB Adverts charging stations managed?

Advertising content on EVB Advert chargers is managed using the Digital Signage Android Player. It is an extremely functional software for remote management of content on the monitor. The software allows you to manage content from any place with Internet access - just log in to the relevant website, upload videos, images, webpages, RSS feeds, remote content, divide the screen into any number of screen areas of any size and position, and much more. The big advantage of Central Stacks software is that the server is in the cloud, so the client does not need to install and maintain it on its side, and therefore the content of any connected media can be managed anywhere and on any device by logging into the server through a web browser.

Our billing model for Central Stacks licenses is also very simple and transparent, unlike many other systems on the market, since the annual license price already includes all the costs incurred by the customer for the system including server maintenance, etc., so at each stage of the project the customer knows exactly how much it will cost him to expand the DS network with additional installations.

How to settle accounts with charger users?

Our stations are equipped with a measurement and billing system, which enables quick settlement with the customer. Settlements are made via mobile applications, RFID cards or a payment terminal.

What is the difference between charging a car with AC and DC?

In the simplest terms, the key distinction lies in the charging speed of the vehicle. In the case of alternating current (AC), the EV is usually charged slower compared to direct current (DC), because the alternating current needs to be converted, and the charging speed depends on how much current the wallbox can supply and how much current the vehicle battery can handle. Charging with alternating current is the most popular method of charging electric vehicles and is widely used, among others, while charging at home. 

DC charging, on the other hand, is a faster charging option often used in public places using chargers with higher power outputs. Unlike AC charging, DC charging delivers direct current to the vehicle battery without a conversion process. The type of charging station you should install depends entirely on your needs and specific requirements. In public areas such as parking lots, a combination of AC and DC charging can provide a pragmatic solution to meet the diverse needs and preferences of different guests.

Are you nationwide?

Yes, we provide installations throughout Sweden, as well as in Europe.

Contact us

We are a dynamic company that places a strong emphasis on technology and innovation. With extensive experience in electrical systems, power solutions, and control mechanisms, we are well-equipped to meet your needs.

Our mission is to provide you with the most sustainable, environmentally friendly, and efficient solutions available. Contact us and discover how we can help you achieve your goals.

Contact